• 75 kVA Single Phase Pole Mounted Transformer
  • 75 kVA Single Phase Pole Mounted Transformer
75 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-75/11
Basic info
Brand Vziman
Model NO. 75 kva Single Phase Pole Mounted Transformer
Rated voltage 11kV
Rated capacity 75kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product overview: 

  •  WONE is a professional manufacturer of distribution transformers with 10 years of manufacturing experience.

  • The single-phase Pole-Mounted transformers designed and produced are usually used for urban and rural power distribution.

  • Input voltages:11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv; Output voltage:240 / 480v, 120 / 240V, etc. 

  • Executive Standards: IEEE C57, ANSI C57, IEC60076 .

Leading technology:

  •  Unique winding technology to improve lightning resistance.

  •   Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure .

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Cylindrical fully sealed construction with self-sealing manual pressure relief valve (according to ANSI specification).

  • Standard NEMA hanger bracket (each device includes pole support bracket plate).

  • Fully sealed structure, maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

winding:

  •  Low voltage windings are made of high quality cable paper wrapped wire.

  • High voltage windings are made of high quality polyurethane enamelled round copper wire.

  • Interlayer insulation using dot adhesive paper, so that the coil bonding into a fixed unit, with excellent insulation resistance.

  • Transformer structure is reliable during normal operation and transportation.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Other:

  •  High strength polymer low pressure casing or high and low pressure porcelain casing.

  • Equipped with ring type full copper tinned terminal.

  •  Install limited current fuses and arresters.

Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

How does the oil-immersed transformer work as a fire protection device?


Protection Devices:
Gas Relay:

When a fault occurs inside the transformer, such as local overheating, electric arc discharge, etc., the insulating oil will decompose and produce gas. The gas relay is installed in the connecting pipeline between the oil tank and the conservator of the oil - immersed transformer.
Once a certain amount of gas is detected, the gas relay will act. It can take different measures according to the severity of the fault. For example, when the light - gas action occurs, an alarm signal will be sent to remind the operation personnel to check; when the heavy - gas action occurs, the power supply of the transformer will be directly cut off to prevent the fault from further expanding and causing a fire.

Fire Isolation Measures:
In the installation environment of the transformer, fire isolation facilities are usually set up. For example, in a substation, an oil - immersed transformer may be installed in an independent fire - proof compartment.
The fire - proof compartment is constructed with fire - resistant materials, such as fire - bricks, fire - proof coatings, etc. These materials can prevent the spread of fire for a certain period of time (such as 1 - 2 hours, depending on the material properties), buying time for firefighters to come and put out the fire.
In addition, fire - proof dikes may be set up around the transformer to prevent the large - area fire caused by the outflow of insulating oil after the rupture of the transformer's oil tank. The fire - proof dikes can limit the leaked oil within a certain range
.


Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the